5. BOILER INFORMATION MENU

DESCRIPTION
00
Secondary fault internal code
01
Heating flow temperature (°C)
02
External temperature (°C)
03
External storage boiler DHW temperature (boiler CH only)
Domestic hot water temperature
04
(boiler with plate exchanger)
Press and hold down
for at least 1 second, to display the information indicated in the following table. Press

6. SWITCHING OFF THE BOILER

To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the "Off" operating mode
off but the electrical circuits remain powered and the anti-freeze function remains active.

7. FILLING THE SYSTEM

Regularly check that the pressure displayed on the pressure gauge B is 1 - 1.5 bar, with the
boiler cold. If the pressure is too low, turn tap "A" to fill the boiler (figure to side).
A
Boiler/system filling tap
B
Pressure gauge
Take special care when filling the heating system. In particular, open any thermostat
valves in the system, ensure the water enters slowly in order to prevent the formation
of air inside the primary circuit until operating pressure is reached. Lastly, vent any
radiators in the system. BAXI declines all liability for damage deriving from the pre-
sence of air bubbles in the primary exchanger due to the incorrect or imprecise observance
of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler from
working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED TECHNICAL SERVICE CENTRE.

8. ROUTINE MAINTENANCE INSTRUCTIONS

To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
DESCRIPTION
05
Water pressure in heating system (bar)
06
Heating return temperature (°C)
07
Fumes sensor temperature (°C)
08
Primary exchanger temperature (°C)
09 - 18