Delivery/return probe control test
160
Fan fault
Intervention of safety thermostat for excess temperature in
178
low temperature system
270
Overheating exchanger
317
162
Call the Authorised Service Centre.
321
163
Call the Authorised Service Centre.
384
164
Parasite flame (internal error)
385
165
Input voltage too low
431
Exchanger sensor faulty
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.

5. BOILER INFORMATION MENU

Press and hold down
for at least 1 second, to display the information indicated in the table. Press
DESCRIPTION
00
Secondary fault internal code
01
Heating supply temperature (°C)
02
Outdoor temperature (°C)
03
Indirect tank DHW temperature (boiler CH only)
Domestic hot water temperature
04
(boiler with plate exchanger)
05
Water pressure in heating system (bar)

6. SWITCHING OFF THE BOILER

To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the "Off" operating mode
off but the electrical circuits remain powered and the anti-freeze function remains active.

7. FILLING THE SYSTEM

Regularly check that the pressure displayed on the pressure gauge "B" is 1 - 1.5 bar,
with the boiler cold. If the pressure is too low, turn tap "A" to fill the boiler (figure to
side).
Take special care when filling the heating system. In particular, open any
thermostat valves in the system, ensure the water enters slowly in order to
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. BAXI declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler
from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED TECHNICAL SERVICE CENTRE.

8. ROUTINE MAINTENANCE INSTRUCTIONS

To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Press and hold down
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
Call the Authorised Service Centre.
DESCRIPTION
06
Heating return temperature (°C)
07
Flue sensor temperature (°C)
08
Primary exchanger temperature (°C)
09 - 13
Manufacturer information
14
Identification Open Therm communication
15 - 18
Manufacturer information
29
for at least 2 seconds.
to exit.
the boiler stays
7220318.01 (1-05/15)
bis