Installation

Actuator (receiver)

INSTALLATION IN A FLUSH-MOUNTED SOCKET

Personal:
Qualified electrician
Removing the housing cover
1.
Undo the screw connection on the device housing with the Phillips screwdriver and remove the
housing.
Connecting
2.
Strip the connection wires to a length of 8 mm (cross-section between 1 mm² and 2.5 mm²).
3.
Insert the connection wires into the corresponding terminals (Fig. 1/6) in accordance with the
wiring diagram (Fig. 3).
Installing the housing base
4.
Attach the housing base to the flush-mounted socket with screws (3.5 x 25 mm) (Fig. 4).