2 Changing the ignition burner injector
Unscrew the connecting nut (14 spanner)
Pull the gas supply pipe towards yourself
Take out the ignition burner nozzle
Fit the new nozzle
Natural gas H/E
Natural gas L/LL
Re-attach the supply tube (14 spanner)
Carry out a gas tightness check.
14
Nozzle diameter
Nozzle marking
(mm)
40
0.40
50
0.50
Adaptation à un autre gaz - Gaz naturel
31/07/07 - 94858457 - 8502-4459B