IDENTIFICATION OF THE COMPONENT PARTS

Figure 2 – AGX Cabinet
6.

CONTROL PANEL

Figure 3 –AGX Control panel
6.1.

Controls and signal devices

The devices on the control panel are as follows:
• main switch with a green pilot light indicating when the refrigerated cabinet is in operation
• chamber fan switch with pilot light (orange) to indicate when the fan is in operation
• compressor switch with pilot light (red) to indicate when the compressor is in operation
• electronic control unit
6.1.1. Main switch
This is for turning on the power supply. The green pilot light comes on to indicate that the cabinet is connected to the electric
power supply.
• light on (pos. I) : the unit is connected
• light off (pos. 0) : the unit is disconnected

6.1.2. Refrigerated chamber fan switch

This serves the purpose of enabling the fan inside the refrigerated chamber. The pilot light indicates the state of its
connection to the electric power supply.
• light on (pos.I): fan running continuously.
• light off (pos.0): fan running intermittently.

6.1.3. Switch for continuous compressor operation

This serves the purpose of enabling the compressor to operate continuously. The pilot light indicates the state of its
connection to the electric power supply. This solution eliminates the thermostat's function.
• light on (pos.I): compressor operating continuously.
• light off (pos.0): compressor operating intermittently.
KEY:
1. Mechanical control panel
2. Adjustabe PVC feet