MOTOR FILTER CLEANING AND REPLACEMENT
1.
Disconnect the flexible hose and open the appliance cover.
2.
Pull the dust collection bag out of its holder so that you can access
the motor filter more easily.
3.
Remove the motor filter (fig. 6). You can clean the filter by tapping
and shaking. If the filter is heavily soiled, you can wash it in lukewarm
water and let it dry properly.
4.
Insert the cleaned or new motor filter into the appliance and close
the cover.
CLEANING AND REPLACEMENT OF THE AIR OUTLET FILTER
Remove the air outlet filter. This type of vacuum cleaner is equipped with an H.E.P.A. filter in the outlet (Fig.
7), which is capable of catching even very fine dust particles. You can clean this filter by tapping and shaking,
and then with a soft brush. After this operation is complete, you can clean a very dirty filter by washing and
rubbing with a soft brush in lukewarm water without any cleaning agents added. It is important to let the
wet parts dry thoroughly. A wet filter would get damaged by vacuum cleaning! Do not use a hair dryer for
drying!
Note: Wet cleaning may cause more wear and tear of the filter and, consequently, shorten its service life.

TROUBLESHOOTING

Problem
Plug inserted into the mains outlet
incorrectly or insufficiently.
Motor does
not run.
The mains outlet is not live.
Motor has
Improper or insufficient air flow.
stopped
Motor overheating fuse activated.
operating.
Front cover
cannot be
Dust bag inserted incorrectly.
closed
Dust bag full or clogged.
Reduced
Obstructed filter.
suction power
Clogged nozzle, tube, or hose.
Vacuum
cleaner heats
Slight heating of the vacuum cleaner is normal and cannot be considered a failure.
up
VP 8320
Cause
Solution
Check the plug connection.
Check for voltage, e.g. by connecting
another appliance.
Disconnect the cable from the socket.
Check and release the air suction
and discharge holes; check the filter's
cleanliness and/or replace the dust bag.
Let the vacuum cleaner cool down.
Check the dust filter installation.
Replace the dust bag.
Clean or replace the filter.
Check and clear the air passage on the
suction and discharge sides.