Herunterladen Diese Seite drucken

Installation; Compatible Transmitters - simu T5 Hz.02 Bedienungsanleitung

Röhrmotor mit integrierter funksteuerung für rolläden und markisen.
Vorschau ausblenden Andere Handbücher für T5 Hz.02:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
T5 Hz.02
GB
Tubular operators with integrated radio for blinds & roller shutters.
®
S.A.S. au capital de 5 000 000 - Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090

Installation

1
- Recommendations :
- Keep a minimum distance of 20 cm between two T5 Hz.02 motors..
- Keep a minimum distance of 30 cm between T5Hz.02 motors and Hz transmitters.
- A radio appliance using the same frequency (433,42MHz) may deteriorate our product's performance (ex. : hi-fi radio headphones).
- Drilling of the tube:
L1
55
20
48*
4
T
L2
(mm)
min.
* :35Nm max.
47
590
508-17
T5Hz.02
230V-50Hz
510-17 515-17 520-17
47
660
525-17 535-17 550-12
47
590
505-35
T5Hz.02
120V-60Hz
510-35 515-18 525-18
47
660
530-12 535-18 550-12
- Assembly :
1
ACIER-STEEL-STAHL-ACERO-ACCIAIO
5
2
3
Wiring
2
- We recommend that the power supply of each motor offers the possibility of being switched off individually.
T5Hz.02

Compatible transmitters

3
1
2
3
4
5
1 : Wall Hz transmitter
4 : 1/5 channels Hz transmitter
2 : Mobile Hz transmitter
5 : Hz timer
3 : Long-range Hz transmitter
- Do not position the transmitter near metal in order to avoid range losses.
5010945B
Read carefully these instructions
before any use.
4xØB /90°
C
A
D
A
ØB
L1
L2
A
ØB
Ø
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
min.
5
603
623
47
590
5
26
5
673
693
47
660
5
26
5
603
623
47
590
5
26
5
673
693
47
660
5
26
Ø4,8 x 10
2
Ø5 x 10
3
9910014
4
9910013
1
25Nm max.
(N)
230V-50Hz
Blue
120V-60Hz
White
Transmitters range :
- 1, 2, 4 and 5 : 20 m through 2 concrete walls .
- 3 : 40 m m through 2 concrete walls.
Location of the "PROG" key on Hz transmitters :
1-2-3
4
PROG
PROG
End limits adjustment
4
- If the installation includes several motors, only one motor is to be powered during this
programming procedure. It will eliminate interferences with the other motor during the procedure.
4.1
- Switch ON the motor.
- Simultaneously press the UP and DOWN keys of a
Hz transmitter. The motor will run for half a
second in one direction, then the other.
The transmitter now controls the Hz.02
motor in unstable mode, move to stage 4.2.
4.2 - Checking the rotation direction
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction , move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the STOP key for at
least 3 seconds. The motor will confirm the reversal of the rotation direction by running for half a second in one
direction, then in the other direction. Move to the stage 4.3.
A
4xØB /90°
C
D
L1
L2
>>
(mm)
(mm)
(mm)
4,2
603
623
4,2
673
693
4,2
603
623
4,2
673
693
4.3 - Adjustement of the end-limits : memorizing the end points
The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position and then the UP position (stage 4.3.a).
- First you can memorize the UP position and then the DOWN position (stage 4.3.b).
1
4.3.a
1
2
2
(PE)
1- Position the motor on the DOWN end limit by using the keys DOWN or UP.
Brown
Green / yellow
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run
Black
Green
automatically in the UP direction.
3- When the motor arrives on the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run
5
PROG
automatically in the DOWN direction.
6- Press 2 seconds the STOP key to validate the setting. The motor will stop, and will run for half a second in
one direction, then in the other direction.
1 / 4
a
>>
OK
>> 4.3
b
>>
3s
2
3
>>>
ON
>>
>> OK >> 4.3
4
5
6
2s
2 / 4

Werbung

loading