10 HP Pump Series, 14" Series • MLP-14/46F
Performance Example
Using the -125 ratio pump with a 100 psi air drive pressure, the liquid flow rate at 10,000 psi outlet
pressure will be 385 cu in/min and air drive consumption at this point will be about 250 Scfm.
Where it is necessary to obtain maximum outlet flow rates up to a predetermined pressure, a Haskel air
pilot switch should be installed sensing the pump outlet pressure to automatically stop the drive (by
cutting off pilot air) at the desired pressure. The air line regulator should be set at maximum available (up
to 125 psi). A Haskel relief valve to prevent over pressurization of the liquid outlet should also be fitted as
a safety precaution. See "Air Pilot Switch" and "Regulating Relief Valves" in Accessories Catalog ACC-
GL.
Weight and Dimensional Information (not to scale)
Models D14-125 and D14-315
4