REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
OPERATION - ELECTRICAL VERSIONS
• Mains versions (ref. 428150 & 428200):
Factory setting: "PROG 1":
PROG
Presence detection
(Fig. K)
(Fig. L)
1
15 - 50cm
2
15 - 50cm
3
15 - 50cm
• Battery-operated versions (ref. 428156 & 428206):
PROG
Presence detection
(Fig. K)
(Fig. L)
3
15 - 50cm
* after last use
MAINTENANCE & CLEANING
• Cleaning chrome and stainless steel: do not use abrasive, chlorine or any other acid-based cleaning products.
Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
Time to recognise
user presence
3 sec.
3 sec.
-
Detection
delay
5 sec.
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
Rinse timing
Pre-rinsing
2 sec.
-
During user's
-
Rinse timing
(Fig. M)
3 - 12 sec.
OFF - 12h -24h *
Duty flush
(Fig. M)
3 - 12 sec.
Every 24 hours *
3 - 12 sec.
Every 24 hours *
presence
Duty flush
(Fig. I)
-
14