Settings
Installer settings
Automatic open window
Enabled
detection
PIN code protection
Disabled
Value of the PIN code
0000
Experts settings
Power
500W
To exit the Expert settings, press
LOAD SHEDDING AND
POWER CUT

LOAD SHEDDING BY PILOT WIRE ONLY

In case of over consumption, an energy power manager or a
disconnector doesnˇt trigger a trip of the general (example:
simultaneous operating of your various household appliances
and others).
This allows you to reduce the energy power subscribed and
therefore optimize your subscription with your energy provider.
IMHOTEP controllers are designed to operate with load shed-
ding systems with pilot wire only.
Orders sent by the pilot wire are executed by the deviceˇs elec-
tronic controller which will apply setpoint corresponding to the
order sent.
The « Stop » order corresponds to the load shedding. When this
order is received, the device switches to "standby" and then
returns to the initial operating mode.
OTHER REMOTELY MANAGEMENT BY
POWER SHUTDOWN
Important : The power supply of the device should be
cut when working on the electrical system only. The
load shedding does not be operated by an additional
system with mechanized power shutdown (with con-
tactor...). Unlike pilot wire shedding, the load shedding
with frequent mechanized power shutdowns can cause
deterioration of the device depending of the quality
of switching elements used. This type of deterioration
would not be covered by the manufacturer's warranty.
If remotely stop or standby orders should be frequently
operated, you must use the pilot wire (refer to previous
"Load shedding by pilot wire only" subsection).

IN CASE OF POWER CUT, BACKUP

- After short power cuts (less than 3 hrs), the device will start up
again without any outside input being required – you do not
have to do anything. All the settings and the correct time will
be saved.
When the main power supply returns, your device will again op-
erate using correct time and the settings that were programmed
before the power cut (as regards desired temperature, operat-
ing mode, programmes, etc.). It will start up again in the mode
which was active before the power outage
- For longer power supply cuts (more than 3 hrs), check the timer
setting. All the other settings are automatically and permanently
saved.
FITTING
Factory settings
CONNECTIONS
ASSEMBLING OF THE CONTROLLER ON
TO THE TOWEL RAILS
Important:
3 times.
Before carrying out any connection tasks, cut off the power
supply to the electronic regulator using the circuit breaker or
the protection fuse in the power supply circuit
• Assembling of the controller on to the towel
1- Fitting the joint to the cartridge heater (the cartridge)
be present on the cartridge
at this location, depending
o-ring(supplied) in place.
2- Connecting the electronic regulator to the cartridge
Bring the electronic regulator close to the cartridge heater,
in order to connect the two insulated female Faston lugs (the
output contacts) to the two male lugs on the cartridge.
Press the lugs together firmly.
18
26
Connection tasks must be carried out by a
qualified professional installer.
rails
Fit the joint (supplied) onto the cartridge heater to ensure
that the latter fits snugly into the electronic regulator:
Another o-ring, may
on the manufacturer.
It will in no way hinder
assembly of the product.
Leave it in place.
However, despite the
presence of o-ring you
still have to put
heater
AND
Bottom of the towel rails
Existing o-ring
Supplied oˇring
18

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nova

Inhaltsverzeichnis