open window detection
(see page
the manual activation (see below).
Overview
Lowering temperature cycle by setting frost protection dur-
ing ventilation of a room by opened window. You can access
the open window detection from the Comfort, Eco and Auto
modes. Two ways to enable the detector:
- Automatic activation, the lowering temperature cycle starts as
soon as the device detects a temperature change.
- Manual activation, the cycle of lowering temperature starts by
pressing a button.
Automatic activation (factory settings)
To disable this mode,
see page 14.
The device detects a temperature fall. An opened window, a
door to the outside, can cause this temperature fall.
Note: The difference between the air from the inside and the
outside must cause a significant temperature fall to be percep-
tible by the device.
This temperature drop detection triggers the change to Frost
Protection mode.
Manual activation
By pressing
for
more than 5 seconds,
the device will switch
on Frost protection
mode.
Frost protection digital meter
When the device performs a lower temperature cycle due to
opened window, a meter appears on the display to show the
cycle time.The counter is automatically reset at the next time
to Frost protection by opened window (automatic or manual
activation).
Stop the Frost protection mode
By pressing one button, you stop the Frost protection mode.
Note: if a temperature rise is detected, the device may return
to the previous mode (active mode before the open window
detection).
14). You can, however, use
• Overview
Your device can be controlled by a central control unit through
a pilot wire, in which case the different operating modes will be
remotely enabled by the programmer.
You can only control the device by pilot wire in the Auto mode.
In the other modes, the orders transmitted by the pilot wire will
not be executed.
In general, a pilot wire control system makes it possible to im-
pose externally a lowering of the temperature setpoint, com-
bined with the internal programming.
If several lowering requests appear simultaneously, priority is giv-
en to the lowest temperature setpoint, thus maximizing savings
(see information on priorities for different modes on page
When a signal is sent from the pilot wire, the self learning optimi-
zation function is suspended.
location
Below the different views of the display for each order sent by
= another location
pilot wire:
This feature allows you to modify temporarily the setting temper-
ature until the next order sent by the central control unit or the
transition to 00:00.
Example:
1- The device is in Auto mode. The central control unit sent an
2- By pressing
Note: The cursor corresponding to the operating mode, i.e Eco
mode in our example, is blinking during the duration of the tem-
porary derogation.
10
17
INFORMATION ABOUT REMOTE CON-
TROL BY PILOT WIRE
Pilot wire = Comfort
Pilot wire = Eco
Comfort - 3,5°C
Pilot wire = Eco - 2
Pilot wire = Frost
Comfort - 2°C
protection
Pilot wire = Boost
Exemption to an order coming from a pilot wire
external programmer
Eco order 15,5°C.
or
, you can change temporarily the
desired temperature up to 18°C for example.
10).
Pilot wire = Eco - 1
Comfort - 1°C
Pilot wire = Stop
(Standby mode)