Herunterladen Inhalt Inhalt Diese Seite drucken

Messner Allrounder Bedienungsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Float Set assembly
1.
Screw the float chamber (1) using screws (3), disks (5) and nuts (6) onto
the float bar (2). Repeat this procedure for all three floats.
2.
Guide the float bars into the square openings on the filter housing from
above and clamp each with two screws (Item 15 of filter housing parts
list).
Push float bars through to reach the desired submersion for the selected
nozzle. Tighten clamping screws firmly!
3.
By carefully filling the three float chambers with water, the system can be
aligned to lie perfectly horizontally in the water and the immersion depth
can be further increased. To do this, unscrew the plug (arrow) and fill with
water.
List of parts supplied / Spare parts
Item
Name
1
Float chamber 18 Liter
2
Float bars 700 Allrounder
3
Hexagonal screw M8 x 90
4
Hexagonal nut M8
5
Disk Ø 8,4
14
Art. no.
Count
104/003266
3
104/003277
3
114/000065
6
114/000066
6
114/000070
6
Assembly 500 and 1000 Stand Set
1.
Screw stand plate (2) with screws (3), two disks (5) and nuts (4) onto
the stand bar (1). Repeat this procedure for all three stands.
2.
Guide stand bars into the square receptacles on the filter housing from
below and clamp each with two screws (Item 15 from the filter housing
parts list). Push stand bars through until the desired immersion depth for
the selected nozzle is reached. Tighten clamping screws firmly!
List of parts supplied / Spare parts
Item Name
Art. no.
1
Stand bar 500
104/003284 3
1
Stand bar 1000
104/003285 0
2
Stand plate Ø 140
104/003287 3
3
Hexagonal screw M6 x 40 114/000068 3
4
Hexagonal nut M6
114/000069 3
5
Disk Ø 6,4
114/000067 6
Lighting Set 3 x 100 Watt Assembly
1.
Mount floodlight (1) with screws (5), disks (7) and nuts (6) onto the
stand (8).
2.
Mount floodlight stand with screws (5), disks (7) and nuts (6) onto the
floodlight bracket (3).
3.
Guide the floodlight bracket into the square receptacles on the filter
housing from above and push through until the floodlight is at the
desired height. Clamp with screws (4).
Count
Count
Stand Set 500 Stand Set 1000
0
3
3
3
3
6
15