Connecting the hob to the main power supply

15. Connecting the hob to the mains power supply

This hob must be connected to the mains power supply only by a suitably quali-
fied person. Before connecting the hob to the mains power supply, check that...
1. ...the domestic wiring system is suitable for the power drawn by the hob.
2. ...the voltage corresponds to the value given in the rating plate
3. ...the power supply cable sections can withstand the load specified on the
rating plate.
To connect the hob to the mains power supply, do not use adapters, reducers,
or branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned
so that its temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable wit-
hout alterations. Any alterations must only be made by a qualified electrician.
The power supply should be connected in compliance with the relevant stan-
dard, or a single-pole circuit breaker. the method of connection is shown below:
3 x 230V~, 3N~
16A
• The installer must ensure that the correct electrical connection has been made
in accordance with the applicable safety regulations.
• If the appliance is connected directly to the mains supply, an omnipolar circuit
breaker must be installed with a minimum gap of 3mm between the contacts.
• If the cable is damaged or needs replacing, this should be done by an after-
sales technician using the proper tools, so as to avoid any accidents.
• The cable must not be bent or compressed.
• The cable must be checked regularly and only replaced by a qualified person.
• The installer must to use the H05GG-F power cord.
50
Black on L1, Brown on L2,
Grey on L3, Blue on N
Note:
If you have any questions,
please contact customer service.
1 x 230-240V~
40A Ø 6mm²
the original cable must
New cable not included in delivery.
!
Device is not suitable for
operation with an EU plug!
When connected to
one phase
not
be used!