Install pop-up waste (65 807), see fold-out page I.
Seal plug-hole rim.
Connect voltage supply via function unit 36 065.
Settings during a power failure
No settings saved by the user will be lost in the event of a
power failure.
Open isolating valve and check connections for
watertightness.

Operation

Using the operating panel
Start/Stop button
Starts and stops the fitting at a preset temperature
(factory setting 38 °C) and full flow rate.
Pause button
Interrupts the flow of water (temperature arrow on
operating panel orange). The flow is resumed by
pressing the button again.
The fitting switches off automatically after a preset
time (factory setting 60 s).
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
Volume
Increases
or decreases the flow rate in a total of
four stages.
Under Calibrate in the chapter setting mode the fitting must to
be proportioned to the local circumstances.
• The display 38 °C must be synchronised with the measured
temperature.
• The minimum and maximum flow rate must be adjusted.
Thus changed the jet image.

Setting mode

Setting mode is activated as follows:
1. Switch on the fitting via the
temperature to 33 °C using the
2. Press the buttons in a clockwise sequence:
3. When, after pressing for the third time, the GROHE Logo
appears, confirm with the button.
Setting mode is now activated and Menu appears in the
display.
This is confirmed using the button on the operating panel.
Adjustment is made using the
mode by pressing the
button.
3
button and set the
button.
buttons. End setting
The following settings can be changed using the operating
panel:
Clock (set time)
13:26
13:26
°C / °F (temperature unit conversion)
°C
°F
Wireless (establish connection with pre set panel)
Press any programme symbol on the pre set panel and hold
for at least 4 s.
(numbers appear on the display if the connection is
successful)
Reset (reset to factory settings)
Factory set? No
Factory set? Yes
Saver (time until screensaver appears)
5 sec
Versions (show relevant software version)
000 (operating panel)
000 (function unit)
Visual (set colour of the temperature arrows)
Red/Blue
Orange
Standby (select screensaver)
Off
GROHE
13:26
Contrast (set background contrast)
12
Preset (program pre set panel)
Setting only possible if the optionally available pre set panel
(Prod. no.: 45 983) is connected.
Resume (time for pause mode)
60 sec
Protect (time for safety shut-off)
60 sec
Max (switching 43 °C stop on/off)
On
Off
The display flashes if 43 °C is exceeded.
Optimal (define start temperature and volume rate)
First make settings in the Calibrate menu.
38 °C
Calibrate (adjust function unit)
Swap Hot Cold
Swap Cold Hot
(connections interchanged)
38 °C | 0
Volume Min | 1
Volume Max | 30

Replacement parts

See fold-out page I (* = special accessories).