Herunterladen Inhalt Inhalt Diese Seite drucken

Switching The Heater On Or Off; The Heating Levels (Figures B And F); The Swivel Function (Figure E); The Overheating Protection Function - Silvercrest SHH 1200 C1 Bedienungs- Und Sicherheitshinweise

Vorschau ausblenden Andere Handbücher für SHH 1200 C1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 64

9.1. Switching the heater on or off

Insert the mains plug into an earthed mains socket that conforms to the specifications in the
"Technical data" section.
You can use the main switch (4) to switch the heater on (1 - ON) and off (0 - OFF).
The middle heating element (7) lights up as soon as the device is switched on.

9.1.1. The heating levels (figures B and F)

The heater has 3 heating levels, each of 400 watts. When you switch on the heater using the main
switch (4), the middle heating element (7) is switched on.
If necessary, you can also switch on the upper heating element (6) and/or the lower heating
element (8).
Press the switch (2) to switch on/off the lower heating element.
Press the switch (3) to switch on/off the upper heating element.

9.2. The swivel function (figure E)

The heater is equipped with a swivel function which can be switched on or off. When the swivel
function is switched on, there is more even heat distribution in the room. When the swivel function is
switched off, the heat is emitted directionally.
 Press the switch (1) to switch on/off the swivel function.

9.3. The overheating protection function

The heater is equipped with an overheating protection function which automatically switches off the
heating elements (6, 7, 8) in the event of internal overheating. After the overheating protection
function is triggered, the heater should be disconnected from the mains. Once the device has
cooled down, it can be reconnected to the mains and used.
RISK OF FIRE!
The overheating protection function is not usually triggered without reason. Check the
following points:
Can the heater freely emit its heat?
Is the heater too close to a wall or any other object?
Is the heater covered?
Are the ventilation slots (10) and the protection grid (5) of the heater free?
Eliminate obvious problems immediately or contact the manufacturer. If the overheating
protection function is repeatedly triggered for no apparent reason, this could indicate the
existence of a technical defect. In this case, stop using the heater and please contact the
manufacturer.
SilverCrest SHH 1200 C1
English - 57

Werbung

Inhaltsverzeichnis
loading