Default position: OFF
OFF position = SAFETY DEVICES ENABLED: the inputs for the safety devices (terminals
20/21) are enabled. If no safety devices are fitted, jumper connect terminals 20 and
21.
ON position = SAFETY DEVICES DISABLED: the input for the safety devices (terminals
20/21) is disabled. If the FAAC CITY traffic bollard does not rise, you can momentarily
disable the safety devices to check if the fault is caused by them.
Note: to fit devices for the detection of metallic masses, please refer to the instructions of
the traffic bollard and to the instructions of the single devices.
Default position: OFF
OFF position = RISE TRAVEL-LIMIT PRESSURE SWITCH ENABLED: in the final rising phase, the
signal from the pressure switch is used as rise travel-limit.
ON position = RISE TRAVEL-LIMIT PRESSURE SWITCH DISABLED: the a.m. function is
disabled. The rise command is kept for the entire duration of the time-out time (cannot
be changed).
Default position: ON
Leave always ON.
THE FOLLOWING CHECKS ARE ALSO TO BE PERFORMED:
Check the operation of the flashing lamp incorporated in the bollard head
Check the operation of the safety inductive loops
Check the operation of the command radio receiver
Visual check of the control unit
After installation, check the correct operation of the traffic bollard, paying special
attention to the safety devices, if any.
DIP – SWITCH 3:
DIP – SWITCH 4:
DIP – SWITCH 5:
FINAL OPERATIONS
FAAC S.p.A. Via Benini, 1 40069 Zola Predosa Bologna (Italia) tel. +39 051 61724