To control the Faac City device with the 624 BLD unit, you need to connect the internal components of
the traffic bollard according to the diagram of fig. 10 (if necessary, use the connection diagram indicated
in the electronic manual of the 624 BLD unit for a more complete overview of the connections):
Specifically, connect the cables coming from the safety pressure switch to the terminal board of
the travel-limit adapter, as shown in the following figure:
Fig. 11
Grey = Pressure Switch
Grey = Pressure Switch
The absence of the opening travel-limit device in the Faac City application requires you to short-
circuit the J3 connector as shown in figure 11.
Take great care when connecting the automatic lowering solenoid valve, if present. This solenoid
valve, in fact, must be supplied with 24 Volt DC via an EXTERNAL POWER UNIT 230Vac-24Vdc able
to supply 1.3 amp connected to the FAN output of the 624 BLD board on terminals 22 and 23 (as
shown in fig. 10).
The heating resistances (optional item), if any, shall be controlled via an external power unit and a
thermostat, which are independent from the 624 BLD board.
You need to change the following programming step on the 624 BLD board (refer to chapter
"PROGRAMMING" of the electronic manual of the 624 BLD board):
First programming step
d F
Set the step
-
programming level by scrolling the steps with the "F" key until you reach the status of the
application without making any further changes.
The a.m. operation is indispensable and must always be carried out at the beginning of a new
installation, BEFORE changing any other parameters in order to customise the application.
In this way, you can set the following basic parameters to control the Faac City on the 624 BLD
board:
Logic A, Pause time 30 seconds, Work Time Out 12 seconds, OUT1 output for Buzzer, OUT2 output for
Head Lights and control parameters of the travel-limit/safety pressure switch.
To customise the operation of the Faac City you can now enter the first and second programming
level, remembering however not to change the parameter
Further details and customisations can be found in the electronic manual of the 624 BLD board,
which is supplied together with the application.
CONNECTION WITH 624 BLD UNIT
PROGRAMMING THE BOARD
03
to the value
to install the FAAC CITY H600 and H800 standard. Exit the first
FAAC S.p.A. Via Benini, 1 40069 Zola Predosa Bologna (Italia) tel. +39 051 61724
d F
that shall remain to
- 15 -
00
.
www.faac.it

Werbung

loading

Diese Anleitung auch für:

275 h800