11/05/10 11:30:47 32Z28610_033
Never connect the different generator models and types.
Never connect a cable other than the receptacle box for parallel
operation.
Connect and remove the receptacle box for parallel operation with
the engine stopped.
For single operation, the receptacle box for parallel operation must
be removed.
1.
Hang the receptacle box for parallel operation on the front handle of
one generator, and tie the longer cable to the front handle of the
other generator with the cable tie.
2.
Connect each cable to the parallel operation sockets and ground
terminal of each generator.
Place two generators at least 1 meter (3 feet) away from each
other during parallel operation.
Take care not to slacken the wire toward the starter grip side.
Connect the longer wire to the generator on which the receptacle
box for parallel operation is not installed.
Do not set the generators with the exhaust side face to face each
other.
CABLE TIE
PARALLEL OPERATION
SOCKET
GROUND TERMINAL
LONGER CABLE
RECEPTACLE BOX
FOR PARALLEL OPERATION
At least 1 meter (3 feet)
FRONT HANDLE