Series 5 Weld Head User's Manual
Micro-Fit Fitting to Micro-Fit Fitting Fixture Block
To align the fixture block, follow these steps:
1. Turn the fixture block over and locate the directional arrows
on the plenum. The arrows point to the appropriate side
plate. See Figure 22.
2. Using the provided 3/32 in. hex wrench, unscrew the four
cap screws in the appropriate side plate just enough to
loosen it from the plenum. See Figure 22 to locate the
appropriate side plate.
3. Turn the fixture block upright and remove the tops of the
CWS-5FSP2 Side Plates. See Figure 23.
4. Using the centering gage, place one Micro-Fit fitting in one
of the side plates.
5. Reinstall that side plate top.
6. Insert the second Micro-Fit fitting into the other side plate
and close its top.
Plenum
Directional
arrows
Cap screws
Side plate
Figure 22 Loosening the Side Plate
Side plate
Centering gage
Figure 23 Removing the Top of the Side
Plate