Series 5 Weld Head User's Manual
1. Place a straight length of tubing (minimum length 1.50 in
[38.1 mm]) in the collets such that it rests across both side
plates.
2. Close and lock the side plate that is not adjustable. See
Figure 18.
3. Lock down the top of the loosened side plate.
4. Tighten the four cap screws in the loosened side plate. Take
care to tighten the screws evenly to prevent the side plate
from slipping.
5. Open the side plates and remove the tubing.
Micro-Fit Fitting-to-Tube Fixture Block
To align the fixture block, follow these steps:
1. Turn the fixture block over and locate the directional arrows
on the plenum. The arrows point to the appropriate side
plate. See Figure 19.
2. Using the provided 3/32 in. hex wrench, unscrew the four
cap screws in the appropriate side plate just enough to
loosen it from the plenum. See Figure 19 to locate the
appropriate side plate.
3. Turn the fixture block upright and release the lever and open
the top of the tube side plate.
4. Choose and install a collet that holds tubing that matches
the outside diameter of the Micro-Fit fitting.
Figure 18
Placing the Tubing
CWS-5FSP2
Plenum
Directional
arrows
Cap screws
Side plate
Figure 19
Loosening the Side Plate