Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning - Oase AquaMax Eco 5000 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für AquaMax Eco 5000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and connection
Connecting the hose
How to proceed:
 A
1. Screw the stepped hose adapter to the outlet.
2. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
Installing the unit
 B
 Never operate the pump in a swimming pond.
 Ensure that the connection to the power supply is at least 2 m from the pond.
Place the unit horizontally on the ground ensuring its stable position.
Commissioning/start-up
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
 Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.

Maintenance and cleaning

Cleaning the device
Recommendation regarding cleaning:
 Clean the unit as required but at least twice a year.
 When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
 In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
 Do not not use cleaning agents or chemical solutions.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.
Cleaning/replacing the impeller unit
How to proceed:
 C
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Remove screws.
5. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
- EN -
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis