Cable shielding can be degraded or cables can be damaged or wear out
l
more quickly if a service loop or bend radius is tighter than 10X the cable
diameter. The bend radius must begin at least six inches from the
connector.
Remove power from the vision controller before connecting or
l
disconnecting any cables or the I/O terminal blocks.
The maximum torque that can be applied to the I/O terminal connectors is
l
0.25 Nm (2.2 in-lb). Applying torque above this limit can damage the
connectors.
Remove power from the vision controller before connecting or
l
disconnecting the 24VDC power connector.
The maximum torque that can be applied to the 24VDC power connector is
l
0.6 Nm (5.3 in-lb). Applying torque above this limit can damage the
connector.
This device is a business-use (Class A) EMC-compliant device. The seller
l
and user are advised to be aware of this fact. This device is intended for use
in areas outside the home.
This device should be used in accordance with the instructions in this
l
manual.