Herunterladen Inhalt Inhalt Diese Seite drucken

Acson international C Serie Installationshandbuch Seite 157

Inverter ceiling concealed split type air conditioner
Vorschau ausblenden Andere Handbücher für C Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
‫ﻻ ﺗﻘﻢ ﻣﻄﻠ ﻘ ﹰ ﺎ ﺑﺘﺠﺎﻭﺯ ﻣﻔﺘﺎﺡ ﺍﻟﻀﻐﻂ ﺍﳌﻨﺨﻔﺾ ﺃﻭ ﻣﺴﺘﺸﻌﺮ ﺍﻟﻀﻐﻂ ﺍﳌﻨﺨﻔﺾ‬
،‫ﻳﺠﺐ ﻓﺼﻞ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ﻗﺒﻞ ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﻷﺳﻔﻞ. ﺑﻌﺪ ﻓﺘﺢ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ‬
‫ﻗﻢ ﺑﺘﻐﻄﻴﺔ ﺍﻟﻠﻮﺣﺔ ﺍﻟﻜﻬﺮﺑﻴﺔ ﺍﳌﻄﺒﻮﻋﺔ ﻭﻟﻮﺣﺔ ﺃﻃﺮﺍﻑ ﺍﻟﺘﻮﺻﻴﻞ ﺑﻠﻮﺡ ﻋﺎﺯﻝ ﻟﺘﺠﻨﺐ‬
.‫ﺍﻟﺼﺪﻣﺔ ﺍﻟﻜﻬﺮﺑﻴﺔ ﺇﺫﺍ ﻻﻣﺴﺖ ﺍﻷﺟﺰﺍﺀ ﺍﳊﻴﺔ ﺑﺪﻭﻥ ﻗﺼﺪ‬
.‫ﻻ ﺗﺘﺮﻙ ﺍﻟﻮﺣﺪﺓ ﺩﻭﻥ ﻣﺮﺍﻗﺒﺔ ﻓﻲ ﻛﺎﻧﺖ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻣﻔﺘﻮﺣﺔ‬
.‫ﺃﻏﻠﻖ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ ﻗﺒﻞ ﻣﻐﺎﺩﺭﺓ ﺍﻟﻮﺣﺪﺓ ﺍﳋﺎﺭﺟﻴﺔ‬
‫ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﺍﻟﻄﺎﻗﺔ ﻭﻗﻢ ﺑﺈﺟﺮﺍﺀ ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﻷﺳﻔﻞ ﻭﻓﻖ ﺍﳋﻄﻮﺍﺕ ﺍﳌﻜﺘﻮﺑﺔ‬
‫ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ‬
‫ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﺍﻟﺴﻠﻚ ﺍﻷﺭﺿﻲ ﺑﺎﻟﻠﻮﺡ ﺍﳋﺎﺹ ﺑﺎﻟﺼﻤﺎﻡ ﺍﳊﺎﺑﺲ‬
(4
)
.‫ﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﺍﻟﻐﻄﺎﺀ ﺍﻷﻣﺎﻣﻲ ﻻ ﻳﺮﺗﻔﻊ ﻷﻋﻠﻲ ﺑﻌﺪ ﺍﻧﺘﻬﺎﺀ ﺍﻟﻌﻤﻞ ﺍﳌﺘﻌﻠﻖ ﺑﺎﻷﺳﻼﻙ‬
‫ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺳﺤﺐ ﺍﻷﺳﻼﻙ ﻣﻦ ﺍﻟﻮﺣﺪﺓ، ﳝﻜﻦ ﺇﺩﺧﺎﻝ ﺍﻷﻧﺒﻮﺏ ﻓﻲ ﻓﺘﺤﺔ ﺍﳋﺮﻭﺝ‬
‫ﺇﺫﺍ ﻟﻢ ﻳﻜﻦ ﻫﻨﺎﻙ ﺃﻧﺒﻮﺏ ﻟﻸﺳﻼﻙ، ﻗﻢ ﺑﺤﻤﺎﻳﺔ ﺍﻷﺳﻼﻙ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﻓﻴﻨﻴﻞ‬
.‫ﳌﻨﻊ ﺗﻘﻄﻊ ﺍﻷﺳﻼﻙ ﺑﺎﳊﻮﺍﻑ ﺍﳊﺎﺩﺓ ﻟﻔﺘﺤﺔ ﺍﳋﺮﻭﺝ‬
‫ﻓﻘﻂ‬
5SLY40/50/60FR
‫ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﻷﺳﻔﻞ‬
.‫ﺃﺛﻨﺎﺀ ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﻷﺳﻔﻞ‬
.‫ﻋﻠﻰ ﺍﻟﻠﻮﺣﺔ ﺍﻷﻣﺎﻣﻴﺔ‬
‫ﺍﻟﻌﻤﻞ ﺍﳌﺘﻌﻠﻖ ﺑﺎﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﻴﺔ‬
‫ﺍﻟﺸﻜﻞ‬
4
.‫ﺣﺘﻰ ﻻ ﻳﻨﺰﻟﻖ‬
.‫ﺃﻏﻠﻖ ﺍﻟﻐﻄﺎﺀ ﺍﻷﻣﺎﻣﻲ ﺑﺈﺣﻜﺎﻡ‬
2
1
‫ﺍﻟﺸﻜﻞ‬
5
2
1
.‫ﺑﺠﻠﺒﺔ ﺣﻤﺎﻳﺔ‬
‫ﺃﺳﻼﻙ ﺗﻮﺻﻴﻞ ﺍﻟﻄﺎﻗﺔ ﻭﺍﻟﺴﻠﻚ ﺍﻷﺭﺿﻲ‬
‫ﺳﻠﻚ ﺍﻟﺘﻮﺻﻴﻞ ﺑﲔ ﺍﻟﺪﻭﺍﺋﺮ ﺍﻟﻜﻬﺮﺑﻴﺔ‬
‫ﺍﳌﻌﻠﻮﻣﺎﺕ ﺍﻟﺘﺎﻟﻴﺔ ﺗﻨﻄﺒﻖ ﻋﻠﻰ ﺍﻟﻄﺮﺍﺯ‬
.5
‫ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﺑﺎﻟﺸﻜﻞ ﺃﻋﻼﻩ، ﻳﻮﺻﻰ ﺑﻨﻘﻞ ﺍﻟﻮﺣﺪﺓ ﻋﻦ ﻃﺮﻳﻖ ﻣﺴﻚ ﺍﳌﻘﺒﺾ‬
.‫ﺍﻷﻳﺴﺮ ﻭﺍﻷﳝﻦ ﺑﺈﺣﻜﺎﻡ. ﺿﻊ ﻳﺪﻳﻚ ﻋﻠﻰ ﺍﻟﺮﻛﻦ ﻟﺘﺠﻨﺐ ﺗﺸﻮﻳﻪ ﺍﻟﻐﻼﻑ‬
.6
W
X
‫ﺍﻟﺸﻜﻞ‬
2a
‫ﻣﺘﻮﻓﺮ‬
‫ﻟﺘﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ‬
(z ،y ،x ،w)
‫ﻗﻄﻊ ﺍﻟﺸﻘﲔ ﲟﻨﺸﺎﺭ ﻣﻌﺪﻧﻲ ﻳﺠﻌﻞ ﻣﻦ ﺍﳌﻤﻜﻦ ﺍﻟﺘﺮﻛﻴﺐ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﳌﻮﺿﺢ‬
‫، ﺍﺻﻨﻊ ﻓﺘﺤﺔ ﺧﺮﻭﺝ‬
‫ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ‬
(2b
.‫ﻣﻨﻬﺎ ﺑﻌﻤﻞ ﺛﻘﺐ ﺧﻼﻝ ﺍﳌﻨﻄﻘﺔ ﺍﳌﺮﻛﺰﻳﺔ ﺣﻮﻝ ﻓﺘﺤﺔ ﺍﳋﺮﻭﺝ‬
.
‫ﺍﻧﻈﺮ ﺷﻜﻞ‬
(2c
‫ﺑﻌﺪ ﺇﻛﻤﺎﻝ ﻋﻤﻠﻴﺔ ﺻﻨﻊ ﺍﻟﻔﺘﺤﺔ، ﻳﻮﺻﻰ ﺑﻮﺿﻊ ﻃﻼﺀ ﺗﺮﻣﻴﻤﻲ ﻋﻠﻰ ﺍﳊﺎﻓﺔ ﻭﺍﻷﺳﻄﺢ‬
‫ﺍﻟﺸﻜﻞ‬
3
‫ﻟﻜﻲ ﺗﺘﻤﻜﻦ ﻣﻦ ﺍﺳﺘﻌﺎﺩﺓ ﻛﻞ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺧﺮﻃﻮﻡ ﺍﻟﺸﺤﻦ، ﺍﺣﺮﺹ ﺩﺍﺋ ﻤ ﹰ ﺎ ﻋﻠﻰ‬
‫ﺍﺳﺘﺨﺪﺍﻡ ﺧﺮﻃﻮﻡ ﺷﺤﻦ ﻣﺮﻥ ﻣﺰﻭﺩ ﺑﺬﺭﺍﻉ ﺩﻓﻊ ﻭﺻﻤﺎﻡ. ﺑﻌﺪ ﺍﻻﻧﺘﻬﺎﺀ ﻣﻦ ﺍﻟﻌﻤﻞ، ﻗﻢ‬
:‫ﺑﺘﺮﻛﻴﺐ ﻏﻄﺎﺀ ﺍﻟﺼﻤﺎﻡ ﺑﺈﺣﻜﺎﻡ ﻓﻲ ﻣﻮﺿﻌﻪ ﲟﻔﺘﺎﺡ ﺭﺑﻂ‬
13.9~ 11.5 N.m.
‫ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺤﺎﻻﺕ ﺍﻟﺘﻲ ﺗﺘﻄﻠﺐ ﺍﻟﺸﺤﻦ ﺍﻟﻜﺎﻣﻞ ﻟﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ، ﻳﻜﻮﻥ ﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍﺀ‬
‫ﺑﻮﺍﺳﻄﺔ ﻣﻨﻔﺬ ﺍﻟﺼﻴﺎﻧﺔ ﺃﻣﺮ ﺇﺟﺒﺎﺭﻱ، ﻻ ﺗﺴﺘﺨﺪﻡ ﻣﻨﻔﺬ ﺍﻟﺼﻤﺎﻡ ﺍﳊﺎﺑﺲ ﻓﻲ ﻫﺬﻩ‬
.‫ﺍﳊﺎﻟﺔ ﻷﻥ ﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍﺀ ﻣﻦ ﺧﻼﻝ ﻣﻨﻔﺬ ﺍﻟﺼﻤﺎﻡ ﺍﳊﺎﺑﺲ ﻻ ﳝﻜﻦ ﺗﻨﻔﻴﺬﻩ ﺑﺎﻟﻜﺎﻣﻞ‬
‫ﺍﻟﻮﺣﺪﺍﺕ ﺍﳋﺎﺭﺟﻴﺔ ﻟﻬﺎ ﻣﻨﻔﺬ ﻭﺍﺣﺪ ﻋﻠﻰ ﺍﻷﻧﺎﺑﻴﺐ. ﻭﻫﻲ ﻣﻮﺟﻮﺩﺓ ﺑﲔ ﺍﳌﺒﺎﺩﻝ ﺍﳊﺮﺍﺭﻱ‬
1
2
١٨
‫ﺍﻟﺸﻜﻞ‬
1
‫ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺍﻟﺸﻜﻞ‬
2b
Z
Y
‫ﺍﻟﺸﻜﻞ‬
2c
‫ﺧﻴﺎﺭﺍﺕ ﻻﲡﺎﻫﺎﺕ )ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ‬
(2a
‫ﻟﻜﻲ ﺗﻘﻢ ﺑﺘﻮﺟﻴﻪ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﻷﺳﻔﻞ‬
)
‫ﱈ ﻟﻬﺬﻩ ﺍﻟﻌﻤﻠﻴﺔ‬
‫ﻳﻮﺻﻰ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺜﻘﺎﺏ‬
)
6
.‫ﺍﶈﻴﻄﺔ ﺑﻬﺎ ﳌﻨﻊ ﺍﻟﺼﺪﺃ‬
‫ﻗﻢ ﺑﺘﻐﻄﻴﺔ ﺍﻟﻔﺘﺤﺎﺕ ﻓﻲ ﺍﻷﻧﺎﺑﻴﺐ ﲟﺎﺩﻩ ﻋﺎﺯﻟﺔ ﻟﺴﺪ‬
‫ﺍﻟﻔﺠﻮﺍﺕ ﳌﻨﻊ ﺩﺧﻮﻝ ﺍﳊﻴﻮﺍﻧﺎﺕ ﺍﻟﺼﻐﻴﺮﺓ ﻭﺍﳊﺸﺮﺍﺕ‬
‫ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﳋﺎﺭﺟﻴﺔ ﳑﺎ ﻗﺪ ﻳﻨﺘﺞ ﻋﻨﻪ ﺍﻧﻘﻄﺎﻉ ﺍﻟﺘﻴﺎﺭ‬
.‫ﻓﻲ ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ‬
‫ﺍﺣﺘﻴﺎﻃﺎﺕ ﺍﻟﺘﻌﺎﻣﻞ ﻣﻊ ﻣﻨﻔﺬ ﺍﻟﺼﻴﺎﻧﺔ‬
‫ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‬
.‫ﻭﺍﻟﺼﻤﺎﻡ ﺭﺑﺎﻋﻲ ﺍﻻﲡﺎﻩ‬
‫ﺍﻟﻨﻘﻞ‬
.1
.2
‫ﻟﺪﻳﻚ‬
4
.‫ﻷﺟﻞ ﺭﺍﺣﺘﻚ‬
.
‫ﺑﺎﻟﺸﻜﻞ‬
2a
.3
.4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis