DIP FUNCTION
ON Always active
8
Photocell
OFF
ON Enabled
9
Photocell test
OFF Disabled
ON
Safety edge
10
type
OFF
ON Always active
11 Safety edge
OFF
ON Enabled
Safety edge
12
test
OFF Disabled
SETTING
DESCRIPTION
Intervention of the photocell during opening or closing
causes the gate to stop. When the photocell restores, the
gate re-opens completely.
Intervention of the photocell during opening is ignored.
NOT active
Intervention of the photocell during closing causes the gate
during opening
to re-open completely.
The control unit performs a photocell operational test before
starting each opening or closing operation. If the photocells
are not operating correctly, the gate does not begin to move
and the light flashes for approx. 8 seconds.
PLEASE NOTE: connect the photocell TX correctly
Conductive
Select this option if using conductive rubber edges with
rubber edge
nominal resistance of 8K2.
Standard or
Select this option if using standard edges with switch
optical edge
normally closed or optical edges.
Intervention of the edge during opening or closing causes
inversion of the direction of movement in order to free the
body that caused the edge to intervene. The gate will be
stopped after approx. 3 seconds.
Intervention of the edge during opening is ignored.
NOT active
Intervention of the edge during closing causes the gate to be
during opening
re-opened completely.
The control unit performs an operational test on the edges
before starting each opening or closing operation. If the
edges are not operating correctly, the gate does not begin to
move and the light flashes for approx. 8 seconds.
DO NOT enable testing if conductive rubber edges are
used or standard edges are used without a suitable
control unit for controlling function.