Herunterladen Inhalt Inhalt Diese Seite drucken

Oszilloscope - Bosch FSA 720 Betriebsanleitung

Fahrzeug-system-analyse
Vorschau ausblenden Andere Handbücher für FSA 720:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
7.1.
Multimeter
Measuring functions
Speed
U battery
U term. 15
U-DC/AC
min./max.
I-1000 A
I-30 A
Resistance
(R-Multi 1)
Pressure P-air
Oil temperature
Air temperature
7.1.3

Oszilloscope

Trigger system:
Free Run (untriggered run at ≥ 1 s).
Auto (curve output also without trigger).
Auto Level (as Auto, trigger threshold at signal center).
Normal (manual trigger threshold, curve output with
trigger event only).
Single sequence.
Trigger edge:
Edge (pos. / neg. on signal).
Trigger sources:
Engine (Trigger on cylinder 1 ... 12 using trigger
clamp, term. 1, KV sensor).
External trigger via term. 1_1 cable or trigger clamp.
Multi measuring cable CH1 / CH2.
Pretrigger proportion:
0 up to 100 %, can be shifted with mouse.
Recording modes:
MaxMin (Peak/Glitchdetect).
Interference pulse recording.
Sample (equidistant scanning).
Memory operating modes and curve output modes:
Roll mode (single point output) with continuous storage
of signals at X-deflections ≥ 1 s.
Legend mode (curve output) with continuous storage
of signals at X-deflections ≥ 1 ms.
Normal mode with storage of last 50 curves displayed
at X-deflection < 1 ms.
Bosch Diagnostics
Measurement range
Resolution
as for engine test
0 - 72 V
0,01 V
0 - 72 V
0,1 V
±200 mV – ±20 V
0,001 V
±20 V – ±200 V
0,01 V
±1000 A
0,1 A
±30 A
0,01 A
0 – 1000 
0,001 
0,1 
1 k – 10 k
100 
10 k – 999 k
0,2 hPa – 2500 hPa
0,1 hPa
-20 °C – 150 °C
0,1 °C
-20 °C – 100 °C
0,1 °C
Measuring system:
8 automatic measuring functions:
$
$
$
$
$
$
$
$
Signal range can be selected: Total curve or between
cursors.
Zoom:
A curve sector can be selected for horizontal and
vertical enlargement.
Cursor:
Moveable cursor with display for:
$
$
$
$
Comparison curves:
Save, load, comment, presetting of scope setup for
live curves.
Storage functions:
Scroll forward / back.
Search functions
e. g. MinMax, pulse duty factor.
Technical data | FSA 70 | 5
Sensors
Connecting cable B+/B–
Connecting cable term. 15
Multi measuring cable CH1 / CH2
Current clamp 1000 A
Current clamp 30 A
Multi measuring cable CH1
Air pressure sensor
Oil temperature sensor
Air temperature sensor
Mean value
Effective value
Min
Max
Peak-to-peak
Pulse
Pulse duty factor
Frequency
x1, x2
delta x
y1 and y2 (channel 1)
y1 and y2 (channel 2)
1 689 979 894
en
|
2007-01-30

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis