Herunterladen Inhalt Inhalt Diese Seite drucken

Lubricating Time; Time Storage; Time Setting - Lincoln Quicklub 236-10697-1 Benutzerinformation

Vorschau ausblenden Andere Handbücher für Quicklub 236-10697-1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
User Manual
Operating Instructions
Pause time
det ermines the frequency of the lubricat ing times (lubrica-
tion cycles) as long as the machine/ ve hicle is in operation.
is started and stopped v ia the machine contact or drivi ng
switch.
is adjustable.

Lubricating time

depends on the system's lubricant requireme nt.
is started and stopped v ia the machine contact or drivi ng
switch.
is adjustable.

Time storage

Time Setting

PCB 4
Cover lid to the control PCB
Page 4 of 20
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Data backup:
The present operating status and the part of the pause time
alrea dy lapsed are stored when the machine contact/ignition
switch is disconnected/switched off.
Reconne ction:
When reconnecting the machine cont act/ignition switch, t he
re maining pause time will continue lapsing f rom where it had
been interrupted. I t will continue lapsing until the pause time
set on the blue rota ry switch (see fi g. PCB 6) will be reached.
Pause time settings should be adapted to the ope rating cycles
re quired for the respective application (see chapter "Pause
time setting", PCB 6).
Data backup:
The present operating status and the part of the lubricating
time already lapsed are stored whe n the machine contact/
ignition switch is disconnected/switched off.
Reconne ction:
When reconnecting the machine cont act/ignition switch, t he
re maining lubricating time will conti nue lapsing from where it
had been inte rrupted. It will continue lapsing until the lubri-
cating time set on the re d rotary swit ch (see f ig. PCB 7) will be
re ached.
Lubricating time settings should be adapted to the lubricant
re quirement of the respe ctive application (see chapter "Lu-
bricating time setting", PCB 7).
Data backup:
Even if the operating voltage is switched off, the times lapsed
will be stored indefinitely (in the EEPROM).
Reconne ction:
When the power supply is switched on again the control unit
continues to operate from the point where it had bee n inter-
rupted.
To set the pause or lubricating time, remove the cover on
the pump housing.
60 01a02
00002 617a
2.6EN-28006-B10
IMPORTANT
Upon completion of the time setting, make
sure to firmly close the cover lid again.
NOTE
To reset a jumper (see fig. PCB 5) rem ove
the printed circuit board.
Whenever t he pump housing has been
opened (e. g. for replacing of the p.c.b. ), the
housing cover (including the foam ed seal)
m ust be replaced.