Herunterladen Inhalt Inhalt Diese Seite drucken

Applications - Lincoln Quicklub 236-10697-1 Benutzerinformation

Vorschau ausblenden Andere Handbücher für Quicklub 236-10697-1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
User Manual
Operating Instructions
1)
This designation shows the versio n of the PCB installed in the pum p. It forms part of the pump designation on the nameplate on each
pump.

Applications

Driving switch F (mobile application)
Machine contact F, printed circuit board 236-10697-1 (V10-V13)
(industrial application)
Machine contact F, printed circuit board 236-10697-2 (V20-V23)
(industrial application)
Page 2 of 20
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Printed Circuit Board V10-V13
T-PCB-010c09
T-PCB-0 10b09
T-PCB-0 10a09
1)
(V20-V23)
The printed circuit boards can be used for the following
applications:
1.
Lubrication cycles only as a function of the machine
working hours.
When the machine contact F (see connection diagrams) is
switched on, the centralized lubrication system is ready for
operation.
2.
Lubrication cycles only as a function of the running hours
of the commercial vehicle.
When the driving switch F (see connection diagrams) is
switched on, the centralized
operation
Printed circuit board V10-V13:
IMPORTANT
On the PCB 236-10697-1 (V10-V13) do not
connect the red core of the connecting
cable to connection 1 (terminal 30) since
terminal 30 is connected internally with
60 01a02
terminal 15.
Printed circuit board V20-V23:
IMPORTANT
The PCB's 236-10697-1 and 236-10697-2
(V20 - V23) differ only as regards their
connection of the terminals. In the case of
PCB 236-10697-2 the terminals 30 and 15
60 01a02
are not connected..
2.6EN-28006-B10
lubrication system is ready for

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

V10V12Quicklub 236-10697-2V13V11

Inhaltsverzeichnis