V. OPERATION
5.1- Intended use
1. This clear water pump is a submersible pump intended for domestic use.
The pump is not intended for artisanal, industrial and/or commercial uses (for ex. Public parks, sports
grounds ...)
2. The pump is designed for routine household uses such as gardening, irrigation systems, pumping water
from tanks, well...
It can be used to suck up clear water from flooded premises with particles in suspension that are less than
[see table II] in diameter. When used to dry out premises (for ex. cellar draining) it is recommended to
place the pump below floor level.
3. The pump is fully submersible: the immersion depth must not exceed [see table II].
4. The pump should not be used for:
- for sucking up liquids or materials that are corrosive, flammable/combustible, explosive r any other
dangerous liquid; fats, oils, sea water, dirty water and waste water (e.g. from toilet, industrial...)
- for pumping or transferring water intended for human consumption or any other food liquids.
5. The pump must not be used for operations not described in this manual.
Any other use, other than that described in the instructions, is likely to damage the pump and to put the user
in serious danger.
6. The temperature of clear water sucked up should not exceed 35°C.
5.2- Operation - automatic functioning mode
Connect pump to mains power.
As this pump is an automatic water pump, it starts operating as soon as it is connected to the electricity
supply, even when there is no water.
5.2.1- Water parameters
Here are the operating settings for this pump:
After 10 seconds, in the condition of no water or when water level is below 40mm, the pump stops
operating.
Then the pump will try to detect the presence of water and restart working, if it detects any water which
level is higher than 40mm, the pump will re-start
The re-start up settings are as follow:
After 6 seconds (1 time),
After 30 seconds (1 time),
After 10 minutes (1 time),
After 1 hour (1 time),
After 5 hours (1 time),
After 24 hours (1 time),
If the pump does not detect water, the pump will stop automatically 10 seconds after the re-start up.
After 24 hours, the pump will repeat over the same re-start up and stop cycle.
Page 15 / 34