IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage
WARNING!
- The warranty does not cover accidents due to improper installation. This pump must be installed in
accordance with local standards and by a qualified person (we recommend you to contact an electrician).
- The fixed pipeline that will connect the pump must include a separation device having contacts with the
opening distance of at least 3 mm in all poles.
- The total head must not exceed 40 m.
4.2- Electrical connection
IMPORTANT! If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or a person with similar qualification in order to avoid any danger.
a) Make sure that the power supply corresponds with the specifications of the device (see rating label).
b) Check that the power cable is not damaged.
2
3×1.0mm
(or exceed 1mm
c) Connect plug to a wall socket 10/16A fitted with a ground connection.
d) Turn the pump for 2 to 3 seconds to perform a dry run of the pump.
Do not operate the pump without water for more than 2 to 3 seconds to avoid overheating. This will cause
permanent damage.
e) Disconnect the pump from the power supply (remove the plug from the wall socket), and then proceed
with delivery/discharge line connection, as described in the following paragraph.
f) Ensure that the electrical connection is protected against water splashing.
g) When operating outdoors, the electrical connections must be splash-proof; they must not lie in water.
h) Extension cords must have sufficient wire cross section; cable drums must be complete unwound.
4.3- Connecting the discharge line (not supplied)
a) Screw the connector (4) provided onto the pump outlet (Fig.1).
b) Wedge the discharge hose (not supplied) on to the connector.
c) Add a fixing collar (hose clamp not supplied) to complete the seal.
Notes: - The discharge hose (not supplied) must have a minimum diameter of 25 mm and must be rigid
and kink resistant to prevent crushing.
- To avoid leakages in the delivery line and get the best performance, ensure to seal the fittings
with Teflon.
Remarks: - All components of the discharge line must be compression-proof.
- All components of the discharge line must be professionally installed
- If the components are not compression-proof or if they are improperly installed, the pressure
line could burst during operation. Risk of injury from liquid spurting out!
4.4- Start-up
1. The pump must be installed in a vertical position: ensure that it is stable during operation.
2. The suction holes must never be obstructed. It is therefore preferable that the pump should never be
placed directly on the ground or on the bottom of the well, pond or vessel.
For example, use a brick to support the pump.
The cable must be at least one cable H07 RN8-F
2
) (line, neutral and earth).