Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a
pH regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks
and damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other
factors may cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.
6 /MAINTENANCE
WINTERIZING
1
Bellow a temperature of water of 15°c, the chemical conditions of the water pull a premature wear of the
chlorinator cell. It is compulsory to switch off its salt chlorinator (« wintering mode »).
Stop the device by putting the production to 0 (0 %). It will set in stand-by mode after few seconds.
If the cell is not fed by the controller box, it will not damage the chlorinator cell if you let it on the
tubing, it will not damage it. Make, then a classical chemical treatment without stabilizer.
At the start up, the next year, switch on again the device by pressing on any touch. If the free
chlorination level is lower than 1 particle by million, make shock chlorination and follow the start up
advises (checking of the water parameters, the rate of salt, of the cell, of the regulation of the chlorine
production percentage).
CLEANING OF THE CELL
2
Self-cleaning avoid the limestone deposits in the cell. However, if the cell is nevertheless scaled, proceed to
a manual cleaning :
Remove the cell and check scale deposit presence on the electrodes.
To remove the scale deposits on the cell, use a cleaner « special cell » or contact your local retailer :
≈
≈
≈
≈
MINISALT – PAPI004086MULTI1- FR/EN/ES/DE – Rev.03.14
Connexions must be
Connexions must be
outside the water
outside the water
cleaning solution
cleaning solution
≈
≈
≈
≈
In line cell
In line cell
Titanium plates
Titanium plates
totally immerged
totally immerged
T cell
T cell
23