Herunterladen Inhalt Inhalt Diese Seite drucken

Installation To Solid Concrete Or Cinder Block - PEERLESS SA752PU Anbringung Und Zusammenbau

Gelenkarm-wandhalter für flachbildschirme von 32 - 52 zoll
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Use wall arm (A) as template to mark mounting holes.
1
The top mounting hole
the desired screen center as shown in fi gure 1.1 on
page 5. Drill three 5/16" (8 mm) dia. holes 2.5" (64 mm)
deep as shown in fi g. 1.3. Insert anchors (D) into holes
fl ush with wall as
and secure
with three wood screws (C) using #3
screwdriver bit
(L).
Insert three fastener caps (F) into wall plate mounting
holes.
WARNING
• Tighten screws so that wall plate is fi rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
fi nishing material. If mounting to concrete surfaces
covered with a fi nishing surface is unavoidable (not
evaluated by UL), the fi nishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied
by installer (not evaluated by UL).
INCORRECT
wall
plate
plaster/
dry wall
should be
7.54" (192 mm) above
shown. Place wall arm over anchors
Level, then tighten all fasteners.
concrete
wall
plate
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (D).
2
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
SOLID CONCRETE
WALL PLATE
CORRECT
C
concrete
F
A
6 of 46
A
C
D
fi g. 1.3
ISSUED: 10-30-09 SHEET #: 095-9297-2 12-04-09
concrete
surface
D
D
CINDER BLOCK

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sa752pu-s

Inhaltsverzeichnis