Herunterladen Inhalt Inhalt Diese Seite drucken

Installation To Solid Concrete Or Cinder Block - PEERLESS Smartmount D-FPF-220 Anbringung Und Zusammenbau

Vorschau ausblenden Andere Handbücher für Smartmount D-FPF-220:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
Make sure that wall plate (AA) is level, use it as a
1
template to mark four mounting holes. The top mounting
slots should be located 4.07" (103 mm) above the
desired screen center as shown in figure 1.1 on page
4. Drill four 5/16" (8 mm) dia. holes to a minimum depth
of 2.5" (64 mm). Insert anchors (DD) in holes flush with
wall as shown (right). Place wall plate over anchors and
secure with #14 x 2.5" screws (CC). Level, then tighten
all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-be aring concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws.
If plaster/drywall is thicker than 5/8" (16 mm),
custom fasteners must be supplied by installer (not
evaluated by UL).
INCORRECT
concrete
wall
plate
plaster/
dry wall
WARNING
CORRECT
concrete
wall
plate
plaster/
dry wall
1
Drill holes and insert anchors (DD).
2
Place plate (AA) over anchors (DD) and secure with screws (CC).
3
Tighten all fasteners.
SOLID CONCRETE
DD
AA
CC
5 of 34
ISSUED: 09-07-07 SHEET #: 202-9223-2 05-07-09
DD
AA
CC
CINDER BLOCK
concrete
surface
DD

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis