GB
Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is not possible.
Specifications:
• Flow pressure
min. 0.5 bar - recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit pressure
reducer.
Avoid major pressure differences between cold and
hot water supply.
• Flow rate at 3 bar flow pressure:
- aerator
- dishwasher connection
• Temperature
Hot water inlet:
Recommended:
• Water connection
• Max. clamping length
Installation
Flush pipes thoroughly!
Installation and connection, see fold-out page III,
Fig. [1] and [2].
Refer to the dimensional drawing on fold-out page I.
Fit swivel spout. Swivel range can be adjusted by
means of stop (A), see Fig. [1].
Note: If the support plate (B) is omitted, the clamping
length can be increased by 15mm, see Fig. [2].
- Cold-water connection (marked blue)
- Hot-water connection (marked red)
- Dishwasher connection
Open hot and cold-water supply and check
connections for leakage!
Operation
a) Lever
Pull lever
Press lever down
Turn lever right
Turn lever left
b) Shut-off valve for dishwasher
Shut-off knob in STOP position = valve closed
Shut-off knob points forwards
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see "replacing the cartridge"
point 1 to 3, Fig. [3] and [4].
max. 10bar
16bar
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Shut off cold and hot water supply!
I. Replacing the cartridge, see Fig. [3].
approx. 12.5 l/min
1. Lever out plug (C).
approx. 19 l/min
2. Remove set screw (D) using a 3mm socket spanner
(maximum) 80 °C
3. Unscrew cap (F).
(energy saving) 60 °C
4. Remove screws (G) and detach complete
cold - right
hot - left
max. 60mm
5. Change either complete cartridge (H) or seals (H1).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals (H1) engage in the
grooves on the housing. Fit screws (G) and tighten
evenly and alternately.
II. Ceramic headpart, see Fig. [5].
1. Remove shut-off knob (J).
2. Pull off snap insert (K).
3. Remove ceramic headpart (L) using a 17mm open-
= right
Assemble in reverse order.
= left
Before installation of the shut-off knob, close the
= G1/2
headpart (L), fit snap insert (K) and shut-off knob (J) in
the STOP position.
III. Unscrew and clean aerator (13 928), see fold-out
page II.
Assemble in reverse order.
= open (water flow)
Replacement parts, see fold-out page II ( * = special
= closed
accessories).
= cold water
= hot water
Care
For directions on the care of this fitting, please refer to
the accompanying Care Instructions.
= valve open
and pull off lever (E).
cartridge (H).
ended spanner.
2