Herunterladen Diese Seite drucken

Agilent Technologies TwisTorr 304 FS series Bedienungshandbuch Seite 163

Vorschau ausblenden Andere Handbücher für TwisTorr 304 FS series:

Werbung

NACK
Unknown
Window
Data Type Error
Out of Range
Win Disabled
TwisTorr 304 FS on board Controller User Manual / 87-901-028-01 (C)
RS 232/RS 485 communication description
1 byte
(0x15)
1 byte
(0x32)
1 byte
(0x33)
1 byte
0x34)
1 byte
(0x35)
Technical Information
The command execution has been
failed
The specified window in the
command is not a valid window
The data type specified in the
command (Logic, Numeric or
Alphanumeric) is not accorded with
the specified Window
The value expressed during a write
command is out of the range value
of the specified Window
The specified window is Read Only
or temporarily disabled (for ex-ample
you can't write the Soft Start when
the Pump is running)