5 - PROGRAMMING
5.1
ENTER MASTER PROGRAMMATION MODE
Set time date on to 12:01 and press simultaneously on the
A L.E.D. will display to show that the valve is in programmation mode. Each programmation step
can be modified.
- Use the
- Press the
5.1.1
Display unit
Notice: if this setting has just been changed, the valve will go around fully and come back to
service mode.
Default setting: [U - - 1]
This setting is identified by the letter U. There are two types:
- [U - - 1] US type: the measure unit is in gallons, time display is 2x12 hours, hardness in grain.
- [U - - 2] metric type: the measure unit is litre, time display is 24 hours, hardness in m
Regenerating way
5.1.2
Notice: if this setting has just been changed, the valve will go around fully and come back to
service mode.
Default setting: [dF]
This display is used in order to tell the card the piston type used on the valve.
- dF
- dFFF
- Fltr
5.1.3
Regeneration type
Default setting: [7 - - 3]
This setting is identified by the number 7. This function allows the setting of the valve regeneration
type. There are 3 possibilities:
- Time clock: The electronics establish that a regeneration is requested when the number of
days between two regenerations has been reached; the new cycle beginning at the preset
time. The setting of the day override establishes the number of days between two
regenerations.
- Weekly chronometric: This type of regeneration is based on the days of the week: Monday,
Tuesday, Wednesday..., Sunday... The electronic triggers a regeneration per predefined day
of the week and at the preset time.
- Metered immediate regeneration: The electronics establish that a regeneration is required
when the softened water volume has reached zero. The regeneration starts
immediately.
- Meter delayed regeneration: The electronics establish that a regeneration is requested when
the volume of softened water used has reached the reserve capacity of the unit. Regeneration
will begin at a preset time; the system will automatically establish a reserve capacity. [7 - - 3]
5.1.4
System capacity
Not visualised in time clock mode: [7 - - 1]
This setting is identified by the letter C. It contains an extended mode Ct, the letter t meaning a
multiplication by 1000.
It enables the regulation of the system capacity in m
The system calculates the water volume that needs to be treated before a regeneration request.
In meter delayed mode, the system will establish a reserve capacity.
i.e. : 35 m
3
°tH
25
and
in order to adjust setting values.
button to advance to the next programmation stage.
: Down flow
: Down flow with brine fill first
: Filter
and
for 5 seconds.
3
xtH°.
E
N
3
x°Th.
G
L
I
S
H
[7 - - 1]
[7 - - 5]
[7 - - 2]
[C–35]