steel front
RIGA 54
Optional mouth surround frame
Technical features:
Power output
Optimal wood consumption
Weight including packaging
Ø stainless steel flue (for minimum height of 2 m)
Ø stainless steel flue (for minimum height of 4 m)
Ø hot-air outlet
External air intake (cross-sectional area)
Fan flow rate (free flow)
Fan power consumption
Heatable volume (insulated according to Italian
Law 10/1991)
kW
9
kg/h
2,5
kg
111
cm
20
cm
16
cm
14 x 2
80
cm
2
m
/h
160 x 2
3
W
20 x 2
m
235
3
-
23 -
Three kits are available, complete with
everything needed to duct the hot air
(page 26):
kit one: only the fi replace room
kit two: fi replace room and 1 adja-
cent rooms
kit three: fi replace room and 2 adja-
cent rooms