1
16
m
6
5
15
18
m
6.3 Electrical connections
Gearmotor, endstop and encoder
Description of the standard electrical connections for left-hand installations
Opening microswitch
Modifications to the electrical connections for right-hand installations
Invert the gearmotor (M-N) and (FA-FC) endstop phases.
3
19
m
m
COM
NC
COM
NC
Closing microswitch
COM
NC
COM
NC
14
14
Orange
White
Orange
Red
White
Red
2
4
13
9
8
12
10
7
ON
11
1
2
3 4 5 6 7 8 9 10
17
Black
Red
brown
blue
24V (d.c.) motor
with encoder
brown
blue