placement of Q-Tee II

Installation distance from a combustible wall

The stove is placed on a non-combustible floor.
using non insulated 150mm I.D. flue pipe, the minimum distance to combustible wall
must be 450 mm from the flue.

normal set-up - corner setting

a. Distance to furniture (min.)
Distance to flammable materials (min.)
b. in front (floor)
c. to the side (floor)
D. to the rear (wall)
e. to the side of the wall
Q-Tee II on a 250 mm high log store
If the stove is to be installed on a wooden floor, it must be covered with a non-combusti-
ble material at least 12 mm thick, in accordance with uk building Regulations
approved Document j. The stove is to be elevated min. 250 mm, for example placed on
a non-combustable base.
Distance to flammable materials (min.)
b. in front (floor)
66
attika
RAIS/
uninsulated flue
1200 mm
575 mm
national/local regulations are followed
400 mm
400 mm
300 mm
E
- User manual for RAIS Q-Tee II
if distances are not shown,
Insulated flue
1200 mm
575 mm
350 mm
400 mm
300 mm