2. SET UP
Air outlet
Air inlet
Min. 50cm
Fig. 3
1. Do not tilt the unit more than 45° when
mounting the legs or castors.
2. Carry the unit by holding from the base.
1) Cut the shipping band and remove the carton.
2) Take out the accessory legs or castors.
Carton
Carton (Base)
Fig. 4
3) Tilt the unit backward to mount the front legs or
castors (work in pair).
Fig. 5
4) Mount the rear legs or castors in the same way.
When mounting the castors, lock the two front
castors before mounting the rear ones, or the unit
will slide when tilted.
5) Before operating the unit, remove all shipping
carton, packing, tape(s) and protective plastic film
on the exterior and top panel. Be careful not to
damage the exterior panels.
6) Position the unit in a selected site.
Gram-webshop.nl
IMPORTANT
Shipping Band
7) Clean the interior with a soft cloth soaked in cold
or warm water containing the proper amount of
neutral cleaner and wrung dry.
8) Level the refrigerator/freezer in both the left-to-
right and the front-to-rear directions (levelness:
within 1°).
3. SHELF AND SHELF CLIP
* The shelf is adjustable in 1" increments. Adjust the
shelf clips according to the height of stored items.
* To attach the shelf clip, insert the upper tab into
an adjust hole in the shelf post to hook the shelf
clip, and push the lower tab into another adjust
hole until it locks in place. To detach the shelf clip,
reverse the above procedure.
Shelf clip
Fig. 6
CAUTION
Attach the shelf clips properly to make the
shelf level.
4. ELECTRICAL CONNECTIONS
IMPORTANT
This refrigerator/freezer is provided with no
power switch or earth leakage circuit breaker,
but with overcurrent protection (fuse) only.
Install a switch rated at least 10A on the main
power supply.
* This refrigerator/freezer must be plugged into the
dedicated power supply which is readily accessible
and has enough capacity. The maximum allowable
voltage variation should not exceed ±10 percent of
the nameplate rating. See the nameplate.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer to avoid any danger.