BRUSH/PAD CLEANING

CAUTION!
Risk of cuts.
It is advisable to wear protective gloves when cleaning the brush/pad because there may be sharp debris.
Remove the brush/pad from the machine, as shown in Use chapter.
Clean and wash the brush/pad with water and detergent.
Check that the brush/pad is integral and not excessively worn; otherwise replace it.

TROBLESHOOTING

PROBLEM
No power
Bad batteries
Batteries need to be charged
Loose battery cable
Batteries not connected properly
Brush motor does
Bad brush switch
Brush circuit breaker has tripped
not run
Rectifier has burned out
Bad wiring
Bad brush motor
Carbon brushes worn out
Bad solenoid
Vacuum motor does
Bad vacuum switch
not run
Bad wiring
Bad vacuum motor
Carbon brushes worn out
Short run time
Batteries need to be charged
Batteries need maintenance
Bad cell in battery(s)
Bad charger
Little or no solution
Bad solution switch
flow
Clogged solution solenoid
Clogged solution filter
Solution line obstructed
Solution flow adjustment knob in need of adjustment
Poor water pick up
Squeegee clogged
Squeegee blades worn
Squeegee not mounted correctly
Vacuum hoses have a hole or are loose
Vacuum hose may be clogged
Drain hose stopper is loose
Batteries need to be charged
CAUSE
USER MANUAL
SOLUTION
Replace batteries
Charge batteries (see Battery Charging)
Tighten loose cable(s)
Follow battery installation instructions
Contact Viper Distributor
Check brush motor for obstructions and reset breaker
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Contact Viper Distributor
Charge batteries (see Battery Charging)
See Battery Maintenance in this manual
Replace batteries
Replace charger
Contact Viper Distributor
Contact Viper Distributor
Remove filter and clean
Remove solution line and clean
Increase flow by twisting solution adjustment knob to
the right. Decrease flow by twisting solution adjustment
knob
Clean debris off squeegee with damp towel
Install new squeegee blades
Confirm that the squeegee assembly is securely fastened
to the machine and not loose fitting.
Check hose connections and make sure they are firm.
Replace hose if damaged.
Check hose for debris and remove any clog.
Tighten drain plug.
Charge batteries (see Battery Charging)