Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Weee - Lincoln Electric HOT ROD 500S Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HOT ROD 500S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system.
locations, due to conducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power S
at the interface point between the user's supply and the public system. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is
connected only to a supply with a short circuit power S

Technical Specifications

HOT ROD 500S:
Input Voltage
380 / 415V  10%
Three Phase
Duty Cycle 40°C / 55°C
(
Based on a 10 min. period
35% / 25%
60% / 35%
100% / 60%
Welding Current Range
50A - 625A
Fuse or Circuit Breaker Size
63A (for 380 / 415V) Superlag
Height
795 mm
Operating Temperature
-10°C to +55°C

WEEE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)
and its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will protect the environment and human health!
English
There may be potential difficulties in ensuring electromagnetic compatibility in those
HOT ROD 500S:
sc
Input Power at Rated Output
43 kVA @ 35% Duty Cycle (40°C)
RATED OUTPUT
Output Current
)
OUTPUT RANGE
RECOMMENDED INPUT CABLE AND FUSE SIZES
PHYSICAL DIMENSIONS
Width
566 mm
WARNING
WARNING
S
≥ 12MVA
sc
greater than or equal to data on the table above.
INPUT
EMC Group / Class
II / A
600A
500A
375A
Maximum Open Circuit Voltage
Input Power Cable
4 Conductor, 10mm
Length
813 mm
Storage Temperature
5
is greater than or equal to:
sc
Frequency
50/60 Hz
Output Voltage
44.0 Vdc
40.0 Vdc
35.0 Vdc
65.5 Vdc
2
(for 380 / 415V)
Weight
203 kg
-25°C to +55°C
07/06
English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis