Placing the fi replace (standing)
The device must be mounted on a suffi ciently sturdy fl oor.
Remove the top and bottom front covers and the glass, as described on page 29.
Place the heater on its base and secure it with 4 M8 bolts. These are located to the left and right of a gas unit.
Level the heater with the adjustable legs.
Make sure to keep fl ammable materials, such as curtains, well clear of the system at a minimum distance of 1.5m.
Installing the reducer
Depending on the length and shape of the concentric channel
system Ø 100 - Ø 150 mm and the outlet construction, a restrictor
with a diameter of Ø 35 mm, Ø 50 mm, Ø 60 mm or Ø 80 mm
according to the tables on page 28 must be installed in the top
of the combustion chamber. The standard culvert for the fl ue
gases is Ø 100 mm.
Ensure that the reducer is properly fi tted. Fitting the
reducer incorrectly may cause defects to the
appliance.