Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba RAV-GM561UT-E Bedienungsanleitung Seite 57

Air conditioner (split type)/4-way smart cassette
Vorschau ausblenden Andere Handbücher für RAV-GM561UT-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
▼ Heat insulation of wiring
connecting port
Side D (height: 8.5 mm)
Side C (height: 4 mm)
Clamp the power supply cable according to the table below
based on the thickness and type.
* The clamp can be mounted on the right or left reverse.
Clamp two cables side-by-side for twin connection.
Cable clamping
Wire type
Specification
4-core stranded
wire 2.5 mm²
Cabtyre cable
4-core stranded
wire 1.5 mm²
111-EN
Adhered surface
Notched section
Power supply terminal board
1 2 3
Remote controller
terminal board
Earth screw
position
Side D
Side C
Cord clamp
GM80, GM110, GM140 type
1. Remove screw A for the fixation of the electrical control box cover and loosened screw B. Slide the cover inside
so that the hook part can be removed (The electrical control box cover remain being hooked on the hinge.).
2. Remove the wiring cover mounting screws (2 locations), and a wiring cover is removed.
3. Connect the indoor/outdoor connecting wire and remote controller wire to the terminal board of the electrical
control box.
4. Tighten the screws of the terminal board securely, and fix the wires with the cord clamp attached to the electrical
control box. (Do not apply tension to the connecting section of the terminal board.)
5. Seal the clearances of each wiring connecting port with the attached seal material. (Cut the redundant portion
of the seal material.)
6. Attach the wiring cover to the original position and fix it with two screws without pinching the wires.
7. Attach the cover of the electrical control box without pinching the wires. (Mount the cover after wiring the ceiling
panel.)
A B
Cover of the electrical control box
– 56 –
Screws A
Screws B
Hinge
Hook section
Screws
Cover of the electrical
control box
Wiring cover
Hinge
Louver connector
(CN510: White)
Seal material
MCU
112-EN