Herunterladen Inhalt Inhalt Diese Seite drucken

Motor And Rack Fitting; Limit Switch Fitting; Maintenance - RIB K500 Gebrauchsanweisungen Und Installation

Selbsthemmender torantrieb fuer schiebetoren
Vorschau ausblenden Andere Handbücher für K500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
Dimensions in mm/inches
Fig. 4
Fig. 5
Fig. 6
Fig. 7
8,8"
1,2"
4,9"
9,2"
1,0"
1,0"
9,2"
RELEASE
To operated after the power supply to the motor has been interrupted.
In order to work manually on the gate, you just need to insert the fitting key and rotate It
3 times counterclockwise (Fig. 8).
In order to carry out the manual operation of the gate leaf the followings must be
checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225
N, for doors/gates for private dwellings, and, 390N for doors/gates for commercial and
industrial sites ( values indicated in 5.3.5 of the EN 12453 norm) .
Fig. 8
MOTOR AND RACK FITTING (Fig.4-5)
Operator K500 comes with a base plate for vertical adjustment.
Such adjustment proves to be useful to set a 1mm clearance between the drive gear and
the rack.
The base plate is provided with three brackets that can be used to fasten the equipment
to the floor. As an alternative, it is possible to obtain the special to type plate for type
K500 (code ACG8108) to be secured directly to the floor.
In addition, it is possible to install the equipment K500 complete with base plate, directly
over the installation plate, as suitable for operator K5 (code ACG8101).
The base plate for operator K500 features four holes for floor securing, through four
expansion studs.
The rack shall be fitted over the motor support, at a certain distance from It.
Its height can be adjusted thanks to the holes In the rack.
The height is adjusted to prevent the gate from resting on the driving gear of the K as it
moves (Fig. 4,5).
To fix the rack on the gate, drill some Ø 5 mm holes and thread them using an M6 screw
tap.
The driving gear needs some 1 mm clearance from the rack.

LIMIT SWITCH FITTING

In order to determine the travel of the moving part, place two cams at the ends of
the rack (Fig. 9).
Move the cams on the rack teeth to adjust their opening and closing travel.
To fix the cams to the rack, tighten the screws issued.
N.B: In addition to the electric stop cams mentioned above, you must also install strong
mechanical stops preventing the gate from sliding out of the top guides.
Fig. 9

MAINTENANCE

To be carried out exclusively by skilled persons after the power supply to the
motor has been interrupted.
Periodically clean and keep the guide free from stones when the gate is standstill.
Pag. 21 di 44
E
N
G
L
I
S
H

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis