PARAMETER
Code
Name
Jerk applied at the beginning of an accele-
F.255 Jerk acc ini 2
ration with ramp sets 2 and 4
Jerk applied at the end of an acceleration
F.256 Jerk acc end 2
with ramp sets 2 and 4
Jerk applied at the beginning of a decele-
F.257 Jerk dec ini 2
ration with ramp sets 2 and 4
Jerk applied at the end of a deceleration
F.258 Jerk dec end 2
with ramp sets 2 and 4
Source for the Ramp time extension
F.260 Ramp extens src
function
F.270 Jump amplitude
Jump frequencies hysteresis
F.271 Jump frequency 1
Jump frequency 1
F.272 Jump frequency 2
Jump frequency 2
It defines the use of START and STOP
P.000 Cmd source sel
commands
P.002 Reversal enable
Reversal enabling
P.003 Safety
Safe start definition
P.010 Control mode
Drive control mode
P.020 Mains voltage
Rated value of the line voltage
P.021 Mains frequency
Rated value of the line voltage frequency
P.040 Motor rated curr
Rated current of the motor
P.041 Motor pole pairs
Pole Pairs of the motor
P.042 Motor power fact
Motor power factor
Measurement of the stator resistance of
P.043 Motor stator R
the motor
P.044 Motor cooling
Motor type cooling
P.045 Motor thermal K
Motor thermal constant
P.060 V/f shape
V/F Curve Type
P.061 Base voltage
Motor base (rated) voltage
P.062 Base frequency
Base frequency
P.063 V/f interm volt
V/F intermediate voltage
AGL50-EV
DESCRIPTION
[0] Null
[1] Analog inp 1
[2] Analog inp 2
[3] Analog inp 3
[0] CtrlWordOnly
[1] CtlWrd & kpd
[0] Disable
[1] Enable
[0] OFF
[1] ON
[0] V/f open loop
[1] V/f clsd loop
230
380
400
420
440
460
480
50
60
[0] Natural
[1] Forced
[0] Custom
[1] Linear
[2] Quadratic
PICK LIST
Selection
Description
Null
Analog input 1
Analog input 2
Analog input 3
PARAMETER
Disabling reverse
rotation
Enabling reverse rotation
START allowed with
RUN temirnal connected
at the power on
START not allowed with
RUN temirnal connected
at the power on
V/f control w/o encoder
feedback
V/f control with encoder
feedback
Self ventilated
Assisted ventilation
V/F curve defined by
the user
Linear characteristic
Quadratic characteristic
Def.
Min
Max
Unit
1.00
0.01
10.00
m/s3
1.40
0.01
10.00
m/s3
1.40
0.01
10.00
m/s3
1.00
0.01
10.00
m/s3
0
0
3
0
0
100
Hz
0
0
250
Hz
0
0
250
Hz
0
0
1
1
0
1
1
0
1
0
0
1
400
230
480
V
50
50
60
Hz
(*)
(*)
(*)
A
2
1
60
(*)
0.01
1
(*)
0
99.99
ohm
0
0
1
30
1
120
min
1
0
2
380
50
528
V
50
25
500
Hz
190
0
P.061
V
Variat.
IPA
0.01
347
0.01
348
0.01
349
0.01
350
338
0.1
339
0.1
340
0.1
341
400
402
403
498
404
405
0.1
406
407
0.01
408
0.01
409
410
411
412
1
413
0.1
414
1
415
55

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis