PARAMETER
Code
Name
I.101 Dig output 2 cfg
Digital output 2 configuration
I.102 Dig output 3 cfg
Digital output 3 configuration
I.103 Reserved
I.150 Exp DigOut 1 cfg
Extended digital output 1 configuration
I.151 Exp DigOut 2 cfg
Extended digital output 2 configuration
I.152 Exp DigOut 3 cfg
Extended digital output 3 configuration
Setting of the Analog Input 1 type refe-
I.200 An in 1 Type
rence (voltage)
I.201 An in 1 offset
Analog Input 1 offset
50
DESCRIPTION
[25] Encoder run
[26] Extern fault
[27] No ext fault
[28] Serial TO
[29] freq=thr1
[30] freq!=thr1
[31] freq>thr1
[32] freq<thr1
[33] freq=thr2
[34] freq!=thr2
[35] freq>thr2
[36] freq<thr2
[37] HS temp=thr
[38] HS temp!=thr
[39] HS temp>thr
[40] HS temp<thr
[41] Output freq
[42] Out freq x 2
[43] CoastThrough
[44] EmgStop
[45] DC braking
[46] Drv OL status
[47] Drv OL warn
[48] Mot OL status
[49] Reserved
[50] Reserved
[51] Contactor
[52] Contactor UP
[53] Contactor DW
[54] Brake cont
[55] Lift start
[56...77] Reserved
[78] Timer 1 out
(fw 03.07)
As for I.100
As for I.100
As for I.100
As for I.100
As for I.100
[0] +/- 10V
[1] 0-10V/0-20mA
PICK LIST
Selection
Description
Active when the RUN
contactor has to be
closed, either for upward
or downward motion
Active when the RUN
contactor has to be
closed for upward motion
Active when the RUN
contactor has to be
closed for downward
motion
Active when the mecha-
nical brake has to be
released
Active when the inverter
output bridge is enabled
and DC brake is not in
progress
Output of Timer 1
Bipolar ± 10V
Unipolar +10V
Def.
Min
Max
Unit
54
0
78
2
0
78
52
0
78
53
0
78
0
0
78
1
0
1
0
-99.9
99.9
%
Variat.
IPA
113
114
116
117
180
118
0.1
119
AGL50-EV