4: CALIBRATION
4.
Calibration
In calibration mode, there is a list of nine calibration values and set up modes.
The list starts at C10 and stops at C18. Calibration related to the speed
transducer has the text ST after calibration number and the depth
transducer has the text DT.
To move to the desired calibration group press UP and DOWN as required.
4.1. Enter and exit calibration
To enter the calibration mode press KEY until the text C10 RET appears.
RET stands for return.
To exit calibration press KEY in C10 RET (return).
4.2. Calibration groups
4.2.1.
C10 Return (RET)
To exit calibration press KEY in this when the text RET is displayed.
4.2.2.
C11 Damping (SEA MID)
Damping is used to get the most stable reading for the situation. Depending
on
the weight of the boat and the sea conditions, you may want to change the
dampening of the reading. If SEA MAX is used, an average of the speed over a
longer period will be displayed. This function will not effect the update rate of the
display.
4.2.3.
C12 Instrument type (Type LOG)
The Star SEA Data instrument can either be operating as a log instrument
(LOG), a depth instrument (DPT) or as a combined log/depth instrument
(ALL).
There is also a demonstration mode built into the instrument (DEM). If LOG
is selected, only log functions will be displayed. If DPT is selected only depth
functions will be displayed.