5.
switch off machine and disconnect it from electricity mains and water supply
6.
remove top by raising it from chassis of appliance (Fig. 5)
7.
remove evaporator cover panel (Fig. 6) and clean top part of evaporator and evaporator cover panel
with water and vinegar solution
8.
remove any sediment from evaporator and evaporator cover panel using a brush with soft bristles and
a non-abrasive sponge
9.
pour plenty of cold water onto the evaporator and with the aid of the brush, direct the sediment
removed into the basin beneath, taking care not to obstruct the holes in the base of the evaporator.
During cleaning of evaporator, take care:
not to bend coils
not to detach water supply pipes
not to remove evaporator thermostat
10.
remove (Fig. 2) and clean with ordinary washing-up liquid:
flag support assembly (1)
ice-cube slide (2)
overflow pipe (3)
sprayer bank (4), taking care to remove side caps (5)
sprayer bank feed pipe (6)
pump filter (7)
11.
clean with the same washing-up liquid:
evaporator cover panel
inner basin
12.
rinse and refit (Fig. 2):
pump filter (7)
sprayer bank feed pipe (6)
sprayer bank (4), after repositioning side caps (5)
overflow pipe (3)
evaporator cover panel (Fig. 6)
13.
prepare to perform the sanitizing operations described in the next chapter

3 SANITIZING

Use a 200 mg/l solution of sodium hypochlorite and water (or a solution of ½ ounce of normal bleach to 1 gallon
of water) or one of the solutions commonly used to disinfect babies' feeding bottles; in this case, check that the
sanitizing product is:
authorized by your country's Ministry of Health
suitable for use with food machines
not harmful to the materials and components of this appliance
For the directions for use and concentrations, please refer to those shown on the packaging and recommended
by the manufacturer. We recommend using the solution at the temperature of 25°C.
1. fill basin with sanitizing solution. Refer to the table for the amount of solution required, depending on daily
production (Fig. 3)
2. refit ice-cube slide (2 in Fig. 2) and flag support assembly (1 in Fig. 2)
3. refit front panel
!! Before connecting the appliance to the mains electricity supply, ensure that all cables and electrical wiring are
perfectly dry.
4. operate ice maker for five one-minute periods, with a five-minute break between them