Herunterladen Inhalt Inhalt Diese Seite drucken

Resistance Measurement (Ch1); Technical Data; 19 6.1 General Data; 19 6.2 Interface Protocols - Bosch KTS 530 Produktbeschreibung

Für die steuergeräte-diagnose
Vorschau ausblenden Andere Handbücher für KTS 530:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
28 | ��S ��� � ��S ��� � ��S ��� | �echnical data
6.

Technical data

6.1
General data
Property
Operating voltage
Power consumption through ve-
hicle battery or power supply
Dimensions (L x W x H)
Weight (without connecting cables)
Operating temperature
Relative humidity
6.2
Interface protocols
The following interfaces with respective protocols are
supported for controller diagnosis in conformance with
ISO 15031:
R
ISO 9141-2 (Communications lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(Communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(Communication lines CAN-H and CAN-L)
R
CAN Single Wire
R
CAN Low Speed
|
1 689 979 987
2008-07-02
6.�
Measuring channel 1 (CH1)
Measuring channel 2 (CH2)
Input resistance > 900 kOhm.
Value�Range
6.�.1
7 VDC — 30 VDC
approx. 6 Watt
Property
170 x 120 x 40 mm
Measurement range 200 mV — 200 V
325 g
Precision CH1
0 °C – 40 °C
90 % (at 25 °C)
Precision CH2
Resolution
6.�.2
Property
Frequency range AC 10 Hz — 400 Hz (-3 dB)
Measurement range 200 mV — 200 V
AC precisi-
on at 100 Hz
EFF precisi-
on at ≤ 100 Hz
Resolution
The measuring ranges and types of measurement "U" and "I" are
*)
peak-to-peak values. This results in the digital display field being
grayed out as soon as the defined measuring range has been
exceeded for a short time (Overload).
6.�.�
Property
Measurement range 100  — 1 M
Precision up
to 200 K
Precision up
to 1 M
Resolution
Input resistance
Multimeter specifications
zero potential
potential based

DC measurement (CH1 and CH2)

Value�Range
±0.75 % of measurement value,
additional ±0.25 % of measurement range
±2 % of measurement value,
additional ±0.5 % of measurement range
100 µV — 100 mV
(depending on measuring range)
AC and effective value measurement
(CH1 and CH2)
*)
Value�Range
±2 % of measurement value, additional
±0.5 % of measurement range
100 µV — 100 mV
(depending on measuring range)

Resistance measurement (CH1)

Value�Range
±0.75 % of measurement value
additional ±0.25 % of measurement range
±2 % of reading
additional ±0.25 % of measurement range
0.1  — 1000 
(depending on measuring range)
> 9 M
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kts 570

Inhaltsverzeichnis