Herunterladen Inhalt Inhalt Diese Seite drucken

Hürner WeldControl 160-R Bedienungsanleitung Seite 34

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Menu Item
Setting
Commission Number
ON / OFF
Welder Code
ON / OFF
Welder Code Always
ON / OFF
Pipe Length
ON / OFF
Welding Number
ON / OFF
Weather Conditions
ON / OFF
ISO Data
ON / OFF
Additional Data
ON / OFF
Print Additional
ON / OFF
Data
Automode
ON / OFF
Check Ambient
ON / OFF
Temperature
Manual Input
ON / OFF
Memory Control
ON / OFF
Inventory Number
Set Time/Date
Select Language
12
EN
if ON: number/identifier of the commission to which the
welding belongs must be entered before every welding; input
of up to 32 alphanumeric characters.
if ON: number/code of the welder who will perform the
welding must be entered before every welding; input of ISO-
standardized welder identification code.
irrelevant if the Welder Code option is set to Off;
if not, then if ON: the welder identification code has to be
entered before every single welding;
if OFF: the welder code has to be entered once and is then
reassigned to all further welding operations until the date
changes.
if ON: the length of both pipes that are going to be welded has
to be entered before the welding;
if OFF: the length of the pipes cannot be entered.
if ON: the machine proposes a welding number that can be
confirmed or changed; if the Commission Number option, too,
is set to On, the proposed welding number is related to the
commission number (see section 4.2.3);
if OFF: no welding number is proposed before the welding
operation.
if ON: the weather conditions in which the welding takes place
have to be selected in a list prior to welding;
if OFF: the weather conditions will not be entered.
if ON: the traceability data required under ISO standards (e.g.,
pipe codes and 2
welding;
if OFF: these ISO data are not requested before welding starts.
if ON: additional data, e.g., address where the welding is
performed, can be entered before each welding; input of up to
20 alphanumeric characters.
if ON: welding reports are sent with all additional data not only
when they are transferred to a stick or PC, but also when they
are printed;
if OFF: printed reports include only the base data.
if ON: if a bead build-up time was previously saved to memory
for the pipe characteristics applicable to the current welding,
the machine terminates the bead build-up stage automatically,
taking the ambient temperature into account;
if OFF: the bead build-up stage has to be terminated manually
by pressing the START/SET key.
if ON: ambient temperature will be checked when machine is
turned on;
If the outside temperature is below 0°C, no welding process
should be started, or appropriate steps should be taken.
if OFF: no check of ambient temperature.
if ON: it is possible to change the welding parameters manually;
if OFF: manual change of welding parameters is impossible.
if ON: machine does not allow further weldings when the
memory is full;
if OFF: machine overwrites the oldest report when the memory
is full.
— M —
In a sub-menu, the number by which the machine/hydraulic unit
used to perform the welding is identified in the inventory of
the operating organization can be entered.
— M —
In a sub-menu, the time and the date of the system clock can be
set.
— M —
In a sub-menu, the language to use for the display screen and
the printed reports can be selected.
HÜRNER WeldControl 160-R User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Description / Possible Data
fitting code) have to be entered before
nd
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Version April 2011